Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cereb Blood Flow Metab ; 42(10): 1905-1919, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35650710

RESUMO

Recent studies have reported functional MRI (fMRI) activation within cerebral white matter (WM) using blood-oxygenation-level-dependent (BOLD) contrast. Many blood vessels in WM run parallel to the fibre bundles, and other studies observed dependence of susceptibility contrast-based measures of blood volume on the local orientation of the fibre bundles relative to the magnetic field or B0 axis. Motivated by this, we characterized the dependence of gradient-echo BOLD fMRI on fibre orientation (estimated by the local diffusion tensor) relative to the B0 axis to test whether the alignment between bundles and vessels imparts an orientation dependence on resting-state BOLD fluctuations in the WM. We found that the baseline signal level of the T2*-weighted data is 11% higher in voxels containing fibres parallel to B0 than those containing perpendicular fibres, consistent with a static influence of either fibre or vessel orientation on local T2* values. We also found that BOLD fluctuations in most bundles exhibit orientation effects expected from oxygenation changes, with larger amplitudes from voxels containing perpendicular fibres. Different magnitudes of this orientation effect were observed across the major WM bundles, with inferior fasciculus, corpus callosum and optic radiation exhibiting 14-19% higher fluctuations in voxels containing perpendicular compared to parallel fibres.


Assuntos
Substância Branca , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Difusão , Imagem de Tensor de Difusão , Imageamento por Ressonância Magnética , Substância Branca/irrigação sanguínea , Substância Branca/diagnóstico por imagem
2.
NMR Biomed ; 34(9): e4567, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34076305

RESUMO

The purpose of this study was to evaluate the use of a double delay alternating with nutation for tailored excitation (D-DANTE)-prepared sequence for banding-free isotropic high-resolution intracranial vessel wall imaging (IC-VWI) and to compare its performance with regular DANTE in terms of signal-to-noise ratio (SNR) as well as cerebrospinal fluid (CSF) and blood suppression efficiency. To this end, a D-DANTE-prepared 3D turbo spin echo sequence was implemented by interleaving two separate DANTE pulse trains with different RF phase-cycling schemes, but keeping all other DANTE parameters unchanged, including the total number of pulses and total preparation time. This achieved a reduction of the banding distance compared with regular DANTE enabling banding-free imaging up to higher resolutions. Bloch simulations assuming static vessel wall and flowing CSF spins were performed to compare DANTE and D-DANTE in terms of SNR and vessel wall/CSF contrast. Similar image quality measures were assessed from measurements on 13 healthy middle-aged volunteers. Both simulation and in vivo results showed that D-DANTE had only slightly lower vessel wall/CSF and vessel wall/blood contrast-to-noise ratio values compared with regular DANTE, which originated from a 10%-15% reduction in vessel wall SNR but not from reduced CSF or blood suppression efficiency. As anticipated, IC-VWI acquisitions showed that D-DANTE can successfully remove banding artifacts compared with regular DANTE with equal scan time or DANTE preparation length. Moreover, application was demonstrated in a patient with an intracranial aneurysm, indicating improved robustness to slow flow artifacts compared with clinically available 3D turbo spin echo scans. In conclusion, D-DANTE provides banding artifact-free IC-VWI up to higher isotropic resolutions compared with regular DANTE. This allows for a more flexible choice of DANTE preparation parameters in high-resolution IC-VWI protocols.


Assuntos
Algoritmos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Líquido Cefalorraquidiano/metabolismo , Simulação por Computador , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído
3.
Curr Opin Behav Sci ; 40: 96-104, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33816717

RESUMO

Limited detection power has been a bottleneck for subject-specific functional MRI (fMRI) studies, however the higher signal-to-noise ratio afforded by ultra-high magnetic fields (≥ 7 Tesla) provides levels of sensitivity and resolution needed to study individual subjects. What may be surprising is that higher imaging resolution may provide both higher specificity and sensitivity due to reductions in partial volume effects and reduced physiological noise. However, challenges remain to ensure high data quality and to reduce variability in ultra-high field fMRI. We discuss session-specific biases including those caused by factors related to instrumentation, anatomy, and physiology-which can translate into variability across sessions-and how to minimize these to help ultra-high field fMRI reach its full potential for individual-focused studies.

4.
Neurol Genet ; 6(2): e401, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32185240

RESUMO

OBJECTIVE: Measures of spinal cord structure can be a useful phenotype to track disease severity and development; this observational study measures the hereditability of cervical spinal cord anatomy and its correlates in healthy human beings. METHODS: Twin data from the Human Connectome Project were analyzed with semiautomated spinal cord segmentation, evaluating test-retest reliability and broad-sense heritability with an AE model. Relationships between spinal cord metrics, general physical measures, regional brain structural measures, and motor function were assessed. RESULTS: We found that the spinal cord C2 cross-sectional area (CSA), left-right width (LRW), and anterior-posterior width (APW) are highly heritable (85%-91%). All measures were highly correlated with the brain volume, and CSA only was positively correlated with thalamic volumes (p = 0.005) but negatively correlated with the occipital cortex area (p = 0.001). LRW was correlated with the participant's height (p = 0.00027). The subjects' sex significantly influenced these metrics. Analyses of a test-retest data set confirmed validity of the approach. CONCLUSIONS: This study provides the evidence of genetic influence on spinal cord structure. MRI metrics of cervical spinal cord anatomy are robust and not easily influenced by nonpathological environmental factors, providing a useful metric for monitoring normal development and progression of neurodegenerative disorders affecting the spinal cord, including-but not limited to-spinal cord injury and MS.

5.
Neuroimage ; 196: 337-350, 2019 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31002965

RESUMO

Functional magnetic resonance imaging (fMRI) is now capable of sub-millimetre scale measurements over the entire human brain, however with such high resolutions each voxel is influenced by the local fine-scale details of the cerebral cortical vascular anatomy. The cortical vasculature is structured with the pial vessels lying tangentially along the grey matter surface, intracortical diving arterioles and ascending venules running perpendicularly to the surface, and a randomly oriented capillary network within the parenchyma. It is well-known that the amplitude of the blood-oxygenation level dependent (BOLD) signal emanating from a vessel depends on its orientation relative to the B0-field. Thus the vascular geometric hierarchy will impart an orientation dependence to the BOLD signal amplitudes and amplitude differences due to orientation differences constitute a bias for interpreting neuronal activity. Here, we demonstrate a clear effect of cortical orientation to B0 in the resting-state BOLD-fMRI amplitude (quantified as the coefficient of temporal signal variation) for 1.1 mm isotropic data at 7T and 2 mm isotropic at 3T. The maximum bias, i.e. the fluctuation amplitude difference between regions where cortex is perpendicular to vs. parallel to B0, is about +70% at the pial surface at 7T and +11% at 3T. The B0 orientation bias declines with cortical depth, becomes progressively smaller closer to the white matter surface, but then increases again to a local maximum within the white matter just beneath the cortical grey matter, suggesting a distinct tangential network of white matter vessels that also generate a BOLD orientation effect. We further found significant (negative) biases with the cortex orientation to the anterior-posterior anatomical axis of the head: a maximum negative bias of about -30% at the pial surface at 7T and about -13% at 3T. The amount of signal variance explained by the low frequency drift, motion and the respiratory cycle also showed a cortical orientation dependence; only the cardiac cycle induced signal variance was independent of cortical orientation, suggesting that the cardiac induced component of the image time-series fluctuations is not related to a significant change in susceptibility. Although these orientation effects represent a signal bias, and are likely to be a nuisance in high-resolution analyses, they may help characterize the vascular influences on candidate fMRI acquisitions and, thereby, may be exploited to improve the neuronal specificity of fMRI.


Assuntos
Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Encéfalo/irrigação sanguínea , Mapeamento Encefálico , Substância Cinzenta/anatomia & histologia , Substância Cinzenta/irrigação sanguínea , Substância Cinzenta/fisiologia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Pia-Máter/anatomia & histologia , Pia-Máter/irrigação sanguínea , Pia-Máter/fisiologia , Substância Branca/anatomia & histologia , Substância Branca/irrigação sanguínea , Substância Branca/fisiologia
6.
Neuroimage ; 187: 68-76, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29398431

RESUMO

Aging and disease-related changes in the arteriovasculature have been linked to elevated levels of cardiac cycle-induced pulsatility in the cerebral microcirculation. Functional magnetic resonance imaging (fMRI), acquired fast enough to unalias the cardiac frequency contributions, can be used to study these physiological signals in the brain. Here, we propose an iterative dual regression analysis in the frequency domain to model single voxel power spectra of echo planar imaging (EPI) data using external recordings of the cardiac and respiratory cycles as input. We further show that a data-driven variant, without external physiological traces, produces comparable results. We use this framework to map and quantify cardiac and respiratory contributions in healthy aging. We found a significant increase in the spatial extent of cardiac modulated white matter voxels with age, whereas the overall strength of cardiac-related EPI power did not show an age effect.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Envelhecimento Saudável , Coração/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Respiração , Idoso , Artefatos , Encéfalo/fisiologia , Análise de Fourier , Humanos , Modelos Neurológicos , Fluxo Pulsátil , Análise de Regressão , Processamento de Sinais Assistido por Computador
7.
Genome Biol ; 18(1): 221, 2017 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-29141654

RESUMO

Open Science is encouraged by the European Union and many other political and scientific institutions. However, scientific practice is proving slow to change. We propose, as early career researchers, that it is our task to change scientific research into open scientific research and commit to Open Science principles.


Assuntos
Bases de Dados como Assunto , Pesquisadores , Ciência
8.
Neuroimage ; 162: 93-105, 2017 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-28864026

RESUMO

The cardiac-induced arterial pressure wave causes changes in cerebral blood flow velocities and volumes that affect the signals in echo-planar imaging (EPI). Using single-echo EPI time series data, acquired fast enough to unalias the cardiac frequency, we found that the cardiac cycle-induced signal fluctuations are delayed differentially in different brain regions. When referenced to the time series in larger arterial structures, the cortical voxels are only minimally shifted but significant shifts are observed in subcortical areas. Using double-echo EPI data we mapped the voxels' "signal at zero echo time", S0, and apparent T2∗ over the cardiac cycle. S0 pulsatility was maximised for voxels with a cardiac cycle-induced timing that was close to the arterial structures and is likely explained by enhanced inflow effects in the cortical areas compared to subcortical areas. Interestingly a consistent T2∗ waveform over the cardiac cycle was observed in all voxels with average amplitude ranges between 0.3-0.55% in grey matter and 0.15-0.22% in white matter. The timing of the T2∗ waveforms suggests a partial volume fluctuation where arteriolar blood volume changes are counterbalanced by changes in CSF volumes.


Assuntos
Encéfalo/fisiologia , Imagem Ecoplanar , Coração/fisiologia , Acoplamento Neurovascular/fisiologia , Fluxo Pulsátil/fisiologia , Artefatos , Humanos
9.
Magn Reson Med ; 77(2): 655-663, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26890988

RESUMO

PURPOSE: To optimize intracranial vessel wall imaging (VWI) at 7T for sharp wall depiction and high boundary contrast. METHODS: A variable flip angle turbo spin echo scheme (SPACE) was optimized for VWI. SPACE provides black-blood contrast, but has less crushing effect on cerebrospinal fluid (CSF). However, a delay alternating with nutation for tailored excitation (DANTE) preparation suppresses the signal from slowly moving spins of a few mm per second. Therefore, we optimized a DANTE-preparation module for 7T. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and signal ratio for vessel wall, CSF, and lumen were calculated for SPACE and DANTE-SPACE in 11 volunteers at the middle cerebral artery (MCA). An exemplar MCA stenosis patient was scanned with DANTE-SPACE. RESULTS: The 7T-optimized SPACE sequence improved the vessel wall point-spread function by 17%. The CNR between the wall and CSF was doubled (12.2 versus 5.6) for the DANTE-SPACE scans compared with the unprepared SPACE. This increase was significant in the right hemisphere (P = 0.016), but not in the left (P = 0.090). The CNR between wall and lumen was halved, but remained at a high value (24.9 versus 56.5). CONCLUSION: The optimized SPACE sequence improves VWI at 7T. Additional DANTE preparation increases the contrast between the wall and CSF. Increased outer boundary contrast comes at the cost of reduced inner boundary contrast. Magn Reson Med 77:655-663, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Assuntos
Angiografia Cerebral/métodos , Interpretação de Imagem Assistida por Computador/métodos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Artéria Cerebral Média/diagnóstico por imagem , Processamento de Sinais Assistido por Computador , Algoritmos , Humanos , Aumento da Imagem/métodos , Infarto da Artéria Cerebral Média/patologia , Artéria Cerebral Média/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
10.
Int J Stroke ; 10(5): 659-64, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25845965

RESUMO

Cerebral small vessel disease (SVD) is a major cause of stroke and cognitive decline. Magnetic resonance imaging (MRI) currently plays a central role in diagnosis, and advanced MRI techniques are widely used in research but are limited by spatial resolution. Human 7 Tesla (7T) MRI has recently become available offering the ability to image at higher spatial resolution. This may provide additional insights into both the vascular pathology itself as well as parenchymal markers which could only previously be examined post mortem. In this review we cover the advantages and limitations of 7T MRI, review studies in SVD performed to date, and discuss potential future insights into SVD which 7T MRI may provide.


Assuntos
Doenças de Pequenos Vasos Cerebrais/patologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...